画像はイメージの場合もございます。
商品詳細は仕様をご覧ください。
INA225AQDGKRQ1

INA225AQDGKRQ1

Product Overview

Category: Integrated Circuit (IC)

Use: The INA225AQDGKRQ1 is a high-precision, low-power, current-shunt monitor IC. It is designed to accurately measure small differential voltages across a shunt resistor and convert them into a proportional current measurement.

Characteristics: - High precision - Low power consumption - Small form factor - Wide input voltage range - Temperature stability

Package: The INA225AQDGKRQ1 is available in a small 8-pin VSSOP package, which allows for easy integration into various electronic systems.

Essence: The essence of the INA225AQDGKRQ1 lies in its ability to provide accurate current measurements in applications where precise monitoring is required.

Packaging/Quantity: The INA225AQDGKRQ1 is typically sold in reels or tubes, with a quantity of 2500 units per reel/tube.

Specifications

  • Supply Voltage Range: 2.7V to 5.5V
  • Input Common-Mode Voltage Range: -0.3V to +26V
  • Output Voltage Range: 0V to Vcc
  • Quiescent Current: 60µA (typical)
  • Gain Error: ±0.25% (maximum)
  • Bandwidth: 200kHz (typical)
  • Operating Temperature Range: -40°C to +125°C

Pin Configuration

The INA225AQDGKRQ1 has the following pin configuration:

  1. V+ (Positive Power Supply)
  2. V- (Negative Power Supply)
  3. REF (Reference Voltage)
  4. IN+ (Positive Differential Input)
  5. IN- (Negative Differential Input)
  6. OUT (Output)
  7. SET (Gain Setting)
  8. NC (No Connection)

Functional Features

  • High accuracy current measurement
  • Low power consumption
  • Wide input voltage range
  • Built-in gain setting for flexible current range selection
  • Temperature stability for reliable operation in various environments

Advantages and Disadvantages

Advantages: - High precision measurements - Low power consumption - Small form factor for easy integration - Wide input voltage range allows for versatile applications - Temperature stability ensures reliable performance

Disadvantages: - Limited output voltage range - Requires external shunt resistor for current measurement

Working Principles

The INA225AQDGKRQ1 operates based on the principle of measuring the voltage drop across a shunt resistor. It amplifies this small differential voltage and converts it into a proportional current measurement. The gain of the amplifier can be set using the SET pin, allowing for flexibility in selecting the desired current range.

Detailed Application Field Plans

The INA225AQDGKRQ1 finds applications in various fields where accurate current monitoring is essential. Some potential application areas include:

  1. Battery management systems
  2. Power supply monitoring
  3. Motor control systems
  4. Solar energy systems
  5. Industrial automation

Detailed and Complete Alternative Models

  1. INA226AQDGKRQ1: Similar to INA225AQDGKRQ1 with additional features such as integrated bus voltage measurement.
  2. INA219AQDGKRQ1: Current-shunt monitor IC with higher precision and built-in I2C interface for digital communication.
  3. INA240AQDGKRQ1: Current-shunt monitor IC with higher common-mode voltage range and lower quiescent current.

These alternative models offer different specifications and features to cater to specific application requirements.

Word count: 410 words

技術ソリューションにおける INA225AQDGKRQ1 の適用に関連する 10 件の一般的な質問と回答をリストします。

Sure! Here are 10 common questions and answers related to the application of INA225AQDGKRQ1 in technical solutions:

1. What is the INA225AQDGKRQ1? - The INA225AQDGKRQ1 is a high-precision, low-drift, automotive-grade current sense amplifier.

2. What is the purpose of using the INA225AQDGKRQ1? - The INA225AQDGKRQ1 is used for accurate measurement of current in various applications, such as battery management systems, motor control, power supplies, and industrial automation.

3. What is the input voltage range of the INA225AQDGKRQ1? - The INA225AQDGKRQ1 has a wide input voltage range of -0.3V to +26V, allowing it to measure both positive and negative currents.

4. What is the output voltage range of the INA225AQDGKRQ1? - The output voltage range of the INA225AQDGKRQ1 is 0V to VREF, where VREF is the reference voltage set by the user.

5. How accurate is the INA225AQDGKRQ1? - The INA225AQDGKRQ1 has a typical accuracy of ±0.25% across the entire temperature range.

6. Can the INA225AQDGKRQ1 measure bidirectional current? - Yes, the INA225AQDGKRQ1 can measure both positive and negative currents, making it suitable for applications where bidirectional current flow is present.

7. Does the INA225AQDGKRQ1 require an external shunt resistor? - Yes, the INA225AQDGKRQ1 requires an external shunt resistor to measure the current. The value of the shunt resistor determines the gain of the amplifier.

8. What is the bandwidth of the INA225AQDGKRQ1? - The bandwidth of the INA225AQDGKRQ1 is 200 kHz, allowing it to accurately measure fast-changing currents.

9. Is the INA225AQDGKRQ1 suitable for automotive applications? - Yes, the INA225AQDGKRQ1 is an automotive-grade device and is designed to meet the stringent requirements of automotive applications.

10. Can the INA225AQDGKRQ1 be used in low-power applications? - Yes, the INA225AQDGKRQ1 has a low quiescent current of 60 µA, making it suitable for low-power applications where power consumption is critical.

Please note that these answers are general and may vary depending on specific application requirements.