画像はイメージの場合もございます。
商品詳細は仕様をご覧ください。
CD40192BPWR

CD40192BPWR

Basic Information Overview

  • Category: Integrated Circuit (IC)
  • Use: Counter/Divider
  • Characteristics: 4-bit synchronous up/down binary counter
  • Package: TSSOP-16
  • Essence: High-speed, low-power CMOS technology
  • Packaging/Quantity: Tape and reel, 2500 units per reel

Specifications

  • Supply Voltage Range: 3V to 18V
  • Operating Temperature Range: -40°C to +85°C
  • Maximum Clock Frequency: 25MHz
  • Counting Modes: Up, Down, Up/Down
  • Number of Stages: 4
  • Reset Function: Yes
  • Carry Output: Yes

Detailed Pin Configuration

  1. CP (Clock Pulse) - Input
  2. MR (Master Reset) - Input
  3. U/D (Up/Down) - Input
  4. PE (Parallel Enable) - Input
  5. Q0 (Output Bit 0) - Output
  6. Q1 (Output Bit 1) - Output
  7. Q2 (Output Bit 2) - Output
  8. Q3 (Output Bit 3) - Output
  9. RC (Ripple Carry) - Output
  10. TC (Terminal Count) - Output
  11. GND (Ground) - Ground
  12. VDD (Supply Voltage) - Power Supply
  13. CE (Count Enable) - Input
  14. P0 (Parallel Data Input Bit 0) - Input
  15. P1 (Parallel Data Input Bit 1) - Input
  16. P2 (Parallel Data Input Bit 2) - Input

Functional Features

  • Synchronous operation with clock pulse input
  • Up, down, or up/down counting modes selectable
  • Parallel load capability for presetting the counter value
  • Master reset for clearing the counter
  • Carry output for cascading multiple counters

Advantages and Disadvantages

Advantages: - High-speed operation - Low power consumption - Wide supply voltage range - Versatile counting modes

Disadvantages: - Limited number of stages (4-bit) - Requires external components for complex applications

Working Principles

The CD40192BPWR is a 4-bit synchronous up/down binary counter. It operates based on the clock pulse input, which triggers the counting action. The counter can count up or down depending on the state of the Up/Down (U/D) input. The Parallel Enable (PE) input allows presetting the counter value using parallel data inputs (P0, P1, P2). The Master Reset (MR) input clears the counter to its initial state. The counter provides various outputs, including the individual bit outputs (Q0-Q3), the ripple carry output (RC), and the terminal count output (TC).

Detailed Application Field Plans

The CD40192BPWR is commonly used in various applications that require counting or dividing functions. Some specific application fields include: 1. Frequency division: The counter can be used to divide an input frequency by a specific factor, enabling frequency scaling in electronic circuits. 2. Event sequencing: It can be utilized to sequence events or control the timing of operations in digital systems. 3. Digital displays: The counter can drive digital displays, such as seven-segment displays, to show numerical values. 4. Industrial automation: It finds applications in industrial automation systems for counting and controlling processes.

Detailed and Complete Alternative Models

Some alternative models to the CD40192BPWR include: 1. CD4029B: 4-bit binary up/down counter with preset and parallel load capability. 2. CD4516B: 4-bit synchronous binary up/down counter with asynchronous reset. 3. SN74LS192: 4-bit synchronous up/down binary counter with parallel load.

Note: The above alternatives are just a few examples, and there are several other models available in the market.

Word count: 399

技術ソリューションにおける CD40192BPWR の適用に関連する 10 件の一般的な質問と回答をリストします。

Sure! Here are 10 common questions and answers related to the application of CD40192BPWR:

  1. Q: What is CD40192BPWR? A: CD40192BPWR is a 4-bit synchronous up/down binary counter with a presettable binary or decade counter mode.

  2. Q: What is the operating voltage range for CD40192BPWR? A: The operating voltage range for CD40192BPWR is typically between 3V and 18V.

  3. Q: How many outputs does CD40192BPWR have? A: CD40192BPWR has four outputs, labeled Q0, Q1, Q2, and Q3.

  4. Q: Can CD40192BPWR be used as a frequency divider? A: Yes, CD40192BPWR can be used as a frequency divider by connecting the appropriate output to the input of another circuit.

  5. Q: Is CD40192BPWR suitable for counting events in a digital system? A: Yes, CD40192BPWR is commonly used for counting events in digital systems due to its synchronous operation and preset capability.

  6. Q: Can CD40192BPWR count both up and down? A: Yes, CD40192BPWR can count both up and down based on the input signals provided.

  7. Q: What is the maximum clock frequency for CD40192BPWR? A: The maximum clock frequency for CD40192BPWR is typically around 20 MHz.

  8. Q: Can CD40192BPWR be cascaded to increase the number of bits in the counter? A: Yes, multiple CD40192BPWR chips can be cascaded together to create counters with more than 4 bits.

  9. Q: Does CD40192BPWR have a reset pin? A: Yes, CD40192BPWR has a synchronous reset pin (MR) that can be used to clear the counter to a specific value.

  10. Q: What is the power supply current consumption of CD40192BPWR? A: The power supply current consumption of CD40192BPWR depends on various factors but typically ranges from a few milliamperes to tens of milliamperes.

Please note that these answers are general and may vary depending on specific datasheet specifications and application requirements.