画像はイメージの場合もございます。
商品詳細は仕様をご覧ください。
P51-750-S-T-D-20MA-000-000

P51-750-S-T-D-20MA-000-000

Product Overview

Category

The P51-750-S-T-D-20MA-000-000 belongs to the category of precision pressure transducers.

Use

It is used for measuring and monitoring pressure in various industrial applications.

Characteristics

  • High accuracy
  • Robust construction
  • Wide operating temperature range
  • Long-term stability

Package

The P51-750-S-T-D-20MA-000-000 comes in a durable and protective packaging to ensure safe transportation and storage.

Essence

The essence of this product lies in its ability to provide accurate and reliable pressure measurements in demanding environments.

Packaging/Quantity

The product is typically packaged individually and is available in single quantities.

Specifications

  • Pressure Range: 0-750 psi
  • Output: 4-20 mA
  • Operating Temperature: -40°C to 85°C
  • Accuracy: ±0.25% full scale
  • Electrical Connection: Packard Metri-Pack 150 Series

Detailed Pin Configuration

The detailed pin configuration of the P51-750-S-T-D-20MA-000-000 is as follows: 1. V+ 2. Signal 3. Ground

Functional Features

  • High precision pressure measurement
  • Compatibility with various industrial systems
  • Long-term reliability
  • Easy integration into existing setups

Advantages

  • Accurate and stable pressure readings
  • Suitable for harsh environments
  • Low maintenance requirements
  • Wide operating temperature range

Disadvantages

  • Higher initial cost compared to standard pressure sensors
  • Requires expertise for installation and calibration

Working Principles

The P51-750-S-T-D-20MA-000-000 operates on the principle of converting applied pressure into an electrical signal, which is then transmitted as a 4-20 mA output.

Detailed Application Field Plans

This precision pressure transducer is suitable for a wide range of applications, including: - Hydraulic systems - Industrial machinery - Process control - Aerospace and defense

Detailed and Complete Alternative Models

Some alternative models to consider include: - P51-1000-A-I-M12-4.5-AB-000-000 - P51-500-A-I-M12-4.5-AB-000-000 - P51-2000-A-I-M12-4.5-AB-000-000

In conclusion, the P51-750-S-T-D-20MA-000-000 precision pressure transducer offers high accuracy and reliability, making it suitable for various industrial applications. Its robust construction and wide operating temperature range make it a valuable component in demanding environments. While it may have a higher initial cost and require expertise for installation, its long-term stability and precise measurements make it a preferred choice for critical pressure monitoring needs.

[Word count: 413]

技術ソリューションにおける P51-750-S-T-D-20MA-000-000 の適用に関連する 10 件の一般的な質問と回答をリストします。

Sure, here are 10 common questions and answers related to the application of P51-750-S-T-D-20MA-000-000 in technical solutions:

  1. What is the operating principle of the P51-750-S-T-D-20MA-000-000 pressure transducer?

    • The P51-750-S-T-D-20MA-000-000 pressure transducer operates on the principle of converting applied pressure into an electrical output signal.
  2. What is the typical application of the P51-750-S-T-D-20MA-000-000 pressure transducer?

    • The P51-750-S-T-D-20MA-000-000 is commonly used in industrial and commercial applications such as hydraulic systems, HVAC systems, and process control.
  3. What is the pressure range of the P51-750-S-T-D-20MA-000-000 pressure transducer?

    • The pressure range of the P51-750-S-T-D-20MA-000-000 pressure transducer is typically 0-750 psi.
  4. What type of output signal does the P51-750-S-T-D-20MA-000-000 pressure transducer provide?

    • The P51-750-S-T-D-20MA-000-000 pressure transducer provides a 4-20 mA output signal.
  5. What are the environmental specifications for the P51-750-S-T-D-20MA-000-000 pressure transducer?

    • The P51-750-S-T-D-20MA-000-000 is designed to operate within a temperature range of -40°C to 85°C and is suitable for use in harsh environments.
  6. Can the P51-750-S-T-D-20MA-000-000 pressure transducer be used with corrosive media?

    • Yes, the P51-750-S-T-D-20MA-000-000 pressure transducer is available with various wetted materials to accommodate different media types, including corrosive fluids.
  7. What is the accuracy of the P51-750-S-T-D-20MA-000-000 pressure transducer?

    • The P51-750-S-T-D-20MA-000-000 pressure transducer typically offers an accuracy of ±0.25% full scale.
  8. Is the P51-750-S-T-D-20MA-000-000 pressure transducer suitable for use in hazardous areas?

    • Yes, the P51-750-S-T-D-20MA-000-000 pressure transducer is available with intrinsically safe and explosion-proof certifications for use in hazardous locations.
  9. What is the response time of the P51-750-S-T-D-20MA-000-000 pressure transducer?

    • The response time of the P51-750-S-T-D-20MA-000-000 pressure transducer is typically very fast, making it suitable for dynamic pressure measurement applications.
  10. Can the P51-750-S-T-D-20MA-000-000 pressure transducer be integrated with PLCs or control systems?

    • Yes, the 4-20 mA output signal of the P51-750-S-T-D-20MA-000-000 pressure transducer can be easily integrated with PLCs, DCS, and other control systems for monitoring and control purposes.