画像はイメージの場合もございます。
商品詳細は仕様をご覧ください。
P51-15-A-UCA-MD-20MA-000-000

P51-15-A-UCA-MD-20MA-000-000

Product Overview

Category

The P51-15-A-UCA-MD-20MA-000-000 belongs to the category of industrial sensors.

Use

It is used for measuring and monitoring pressure in various industrial applications.

Characteristics

  • High precision measurement
  • Robust construction for industrial environments
  • Compatibility with different media
  • Wide operating temperature range

Package

The sensor is typically packaged in a durable housing suitable for industrial use.

Essence

The essence of the P51-15-A-UCA-MD-20MA-000-000 lies in its ability to provide accurate and reliable pressure measurements in challenging industrial settings.

Packaging/Quantity

The sensor is usually packaged individually and is available in varying quantities based on customer requirements.

Specifications

  • Pressure Range: 0-15 bar
  • Output: 4-20mA
  • Operating Temperature: -40°C to 125°C
  • Material: Stainless steel
  • Electrical Connection: M12 connector

Detailed Pin Configuration

The detailed pin configuration of the P51-15-A-UCA-MD-20MA-000-000 is as follows: - Pin 1: Power supply + - Pin 2: Power supply - - Pin 3: Signal output - Pin 4: Not connected

Functional Features

  • Accurate pressure measurement
  • Compatibility with various media
  • Compact and rugged design
  • Easy integration into industrial systems

Advantages

  • High precision measurement
  • Suitable for harsh industrial environments
  • Wide operating temperature range
  • Reliable and long-lasting performance

Disadvantages

  • Limited to specific pressure range
  • Requires compatible interface for data acquisition

Working Principles

The P51-15-A-UCA-MD-20MA-000-000 operates on the principle of strain gauge technology, where the applied pressure causes deformation in the sensing element, leading to a change in electrical resistance. This change is then converted into a proportional electrical signal for pressure measurement.

Detailed Application Field Plans

The P51-15-A-UCA-MD-20MA-000-000 is widely used in industries such as: - Manufacturing - Petrochemical - Automotive - Aerospace - Energy

Its applications include pressure monitoring in hydraulic systems, process control, and equipment safety.

Detailed and Complete Alternative Models

Some alternative models to the P51-15-A-UCA-MD-20MA-000-000 include: - P51-10-A-P-I12-5V-000-000 - P51-20-B-UCA-MD-10V-000-000 - P51-30-C-UCA-MD-4-20MA-000-000

These models offer similar functionality with variations in pressure range, output signal, and material construction.

This comprehensive entry provides an in-depth understanding of the P51-15-A-UCA-MD-20MA-000-000, covering its specifications, features, applications, and alternatives.

技術ソリューションにおける P51-15-A-UCA-MD-20MA-000-000 の適用に関連する 10 件の一般的な質問と回答をリストします。

  1. What is P51-15-A-UCA-MD-20MA-000-000?

    • P51-15-A-UCA-MD-20MA-000-000 is a specific model or part number used in technical solutions, typically related to sensors or control systems.
  2. What is the application of P51-15-A-UCA-MD-20MA-000-000?

    • The application of P51-15-A-UCA-MD-20MA-000-000 can vary, but it is commonly used in pressure sensing and monitoring applications in industrial and commercial settings.
  3. How does P51-15-A-UCA-MD-20MA-000-000 work?

    • P51-15-A-UCA-MD-20MA-000-000 is a pressure sensor that operates by converting pressure into an electrical signal, typically measured in milliamps (mA), which can then be used for monitoring or control purposes.
  4. What are the key features of P51-15-A-UCA-MD-20MA-000-000?

    • Some key features of P51-15-A-UCA-MD-20MA-000-000 may include its pressure range, accuracy, output signal, temperature range, and compatibility with different media types.
  5. What are the typical industries or applications that use P51-15-A-UCA-MD-20MA-000-000?

    • P51-15-A-UCA-MD-20MA-000-000 is commonly used in industries such as HVAC, automotive, aerospace, oil and gas, and manufacturing for pressure monitoring and control.
  6. What are the installation requirements for P51-15-A-UCA-MD-20MA-000-000?

    • The installation of P51-15-A-UCA-MD-20MA-000-000 may involve considerations such as mounting orientation, sealing requirements, electrical connections, and calibration procedures.
  7. How do I troubleshoot issues with P51-15-A-UCA-MD-20MA-000-000?

    • Troubleshooting P51-15-A-UCA-MD-20MA-000-000 may involve checking for proper electrical connections, verifying calibration, inspecting for damage or contamination, and ensuring compatibility with the application.
  8. What are the maintenance requirements for P51-15-A-UCA-MD-20MA-000-000?

    • Maintenance of P51-15-A-UCA-MD-20MA-000-000 may include periodic calibration checks, inspection for wear or damage, and ensuring environmental conditions are within specified limits.
  9. Are there any safety considerations when using P51-15-A-UCA-MD-20MA-000-000?

    • Safety considerations may include handling the sensor according to manufacturer guidelines, ensuring proper grounding and electrical safety measures, and following any specific precautions related to the application.
  10. Where can I find technical documentation for P51-15-A-UCA-MD-20MA-000-000?

    • Technical documentation for P51-15-A-UCA-MD-20MA-000-000 can typically be found on the manufacturer's website, including datasheets, installation guides, and user manuals.