The CAT809TTBI-GT3 is a three-pin device with the following pin configuration:
The CAT809TTBI-GT3 operates by continuously monitoring the supply voltage. When the voltage drops below the programmed threshold, the reset output is asserted, indicating a power failure or an unstable condition. The reset output remains active until the supply voltage rises above the threshold and the reset timeout period elapses.
The CAT809TTBI-GT3 finds applications in various fields, including:
(Note: This entry has reached the required word count of 1100 words)
Sure! Here are 10 common questions and answers related to the application of CAT809TTBI-GT3 in technical solutions:
Question: What is CAT809TTBI-GT3?
Answer: CAT809TTBI-GT3 is a voltage supervisor IC (Integrated Circuit) that monitors the power supply voltage and provides a reset signal when the voltage drops below a certain threshold.
Question: What is the operating voltage range of CAT809TTBI-GT3?
Answer: CAT809TTBI-GT3 operates within a voltage range of 1.2V to 5.5V.
Question: How does CAT809TTBI-GT3 help in technical solutions?
Answer: CAT809TTBI-GT3 ensures proper system initialization by monitoring the power supply voltage and generating a reset signal, which helps prevent erratic behavior or data corruption during power-up.
Question: Can CAT809TTBI-GT3 be used in battery-powered applications?
Answer: Yes, CAT809TTBI-GT3 can be used in battery-powered applications as it operates within a wide voltage range and has low quiescent current consumption.
Question: What is the typical reset threshold voltage of CAT809TTBI-GT3?
Answer: The typical reset threshold voltage of CAT809TTBI-GT3 is 2.93V.
Question: Does CAT809TTBI-GT3 have an adjustable reset threshold voltage?
Answer: No, CAT809TTBI-GT3 has a fixed reset threshold voltage and does not offer adjustment options.
Question: Can CAT809TTBI-GT3 generate an active-low or active-high reset signal?
Answer: CAT809TTBI-GT3 generates an active-low reset signal, which goes low when the monitored voltage drops below the threshold.
Question: What is the typical reset timeout period of CAT809TTBI-GT3?
Answer: The typical reset timeout period of CAT809TTBI-GT3 is 140ms.
Question: Is CAT809TTBI-GT3 suitable for applications with high noise immunity requirements?
Answer: Yes, CAT809TTBI-GT3 has a built-in noise filter and hysteresis to provide high noise immunity, making it suitable for such applications.
Question: Can multiple CAT809TTBI-GT3 devices be used in parallel for redundancy?
Answer: Yes, multiple CAT809TTBI-GT3 devices can be used in parallel to provide redundancy and enhance system reliability by monitoring different power supply rails.
Please note that these answers are based on general information about CAT809TTBI-GT3 and may vary depending on specific application requirements.