MAX708TCPA+

MAX708TCPA+ - English Editing Encyclopedia Entry

Product Overview

Category

MAX708TCPA+ belongs to the category of integrated circuits (ICs).

Use

This product is commonly used for voltage monitoring and reset functions in microcontroller-based systems.

Characteristics

  • Voltage monitoring range: 1.8V to 5V
  • Reset timeout period: Adjustable from 1ms to 60s
  • Low supply current: Typically 7µA
  • Small package size: 8-pin PDIP (Plastic Dual In-Line Package)
  • RoHS compliant

Package and Quantity

The MAX708TCPA+ is available in an 8-pin PDIP package. It is typically sold in reels or tubes, with a quantity of 250 units per reel/tube.

Specifications

  • Supply Voltage Range: 1.0V to 5.5V
  • Operating Temperature Range: -40°C to +85°C
  • Reset Threshold Accuracy: ±2.5%
  • Reset Timeout Period Accuracy: ±10%
  • Quiescent Current: 7µA (typical)

Pin Configuration

The MAX708TCPA+ has the following pin configuration:

```


| | --| VCC GND |-- Pin 1: Ground (GND) --| MR RST |-- Pin 2: Manual Reset Input (MR) --| RESET VCC |-- Pin 3: Power Supply (VCC) --| GND GND |-- Pin 4: Ground (GND) --| GND GND |-- Pin 5: Ground (GND) --| GND GND |-- Pin 6: Ground (GND) --| GND GND |-- Pin 7: Ground (GND) --| GND GND |-- Pin 8: Ground (GND) |___________| ```

Functional Features

  • Voltage monitoring and reset generation
  • Adjustable reset timeout period
  • Manual reset input for immediate system reset
  • Low supply current for power efficiency
  • Wide operating voltage range for compatibility with various systems

Advantages

  • Provides reliable voltage monitoring and reset functionality
  • Adjustable reset timeout period allows customization for different applications
  • Low quiescent current minimizes power consumption
  • Small package size enables space-saving designs
  • RoHS compliant, ensuring environmental friendliness

Disadvantages

  • Limited to 8-pin PDIP package, may not be suitable for all form factors
  • Reset timeout period accuracy is ±10%, which may not meet the requirements of some precision applications

Working Principles

The MAX708TCPA+ monitors the supply voltage and generates a reset signal when the voltage falls below a preset threshold. The reset signal remains active until the supply voltage rises above the threshold and the reset timeout period elapses. The reset timeout period can be adjusted using an external capacitor.

Application Field Plans

The MAX708TCPA+ finds applications in various fields, including: 1. Microcontroller-based systems 2. Embedded systems 3. Industrial automation 4. Consumer electronics 5. Automotive electronics

Alternative Models

Other alternative models that provide similar functionality to the MAX708TCPA+ include: 1. MAX705CPA+ 2. MAX706TESA+ 3. MAX707ESA+

These models offer comparable voltage monitoring and reset features, but may have different package options or additional functionalities.

In conclusion, the MAX708TCPA+ is a versatile integrated circuit used for voltage monitoring and reset functions in microcontroller-based systems. Its adjustable reset timeout period, low power consumption, and small package size make it suitable for various applications. However, designers should consider alternative models based on specific requirements and form factor constraints.

技術ソリューションにおける MAX708TCPA+ の適用に関連する 10 件の一般的な質問と回答をリストします。

Sure! Here are 10 common questions and answers related to the application of MAX708TCPA+ in technical solutions:

  1. Q: What is the MAX708TCPA+? A: The MAX708TCPA+ is a microprocessor supervisory circuit that monitors the power supply voltage of a system and provides a reset signal to the microprocessor when necessary.

  2. Q: What is the purpose of using the MAX708TCPA+ in a technical solution? A: The MAX708TCPA+ ensures reliable operation of microprocessors by monitoring the power supply voltage and generating a reset signal if the voltage falls below a specified threshold.

  3. Q: How does the MAX708TCPA+ work? A: The MAX708TCPA+ continuously monitors the power supply voltage using an internal voltage reference. If the voltage drops below the specified threshold, it generates a reset signal to restart the microprocessor.

  4. Q: Can the MAX708TCPA+ be used with different microprocessors? A: Yes, the MAX708TCPA+ can be used with a wide range of microprocessors as long as the voltage requirements are within its operating range.

  5. Q: What is the operating voltage range of the MAX708TCPA+? A: The MAX708TCPA+ operates within a voltage range of 1.0V to 5.5V.

  6. Q: Does the MAX708TCPA+ have any adjustable parameters? A: No, the MAX708TCPA+ does not have any adjustable parameters. It is pre-configured to operate at a specific voltage threshold.

  7. Q: Can the MAX708TCPA+ be used in battery-powered applications? A: Yes, the low quiescent current consumption of the MAX708TCPA+ makes it suitable for battery-powered applications where power efficiency is crucial.

  8. Q: Does the MAX708TCPA+ have any built-in protection features? A: Yes, the MAX708TCPA+ includes a watchdog timer that can be used to detect and recover from software or hardware failures.

  9. Q: Can the MAX708TCPA+ be used in automotive applications? A: Yes, the MAX708TCPA+ is designed to meet automotive industry standards and can be used in automotive applications where reliable microprocessor operation is critical.

  10. Q: Are there any specific layout considerations when using the MAX708TCPA+? A: Yes, it is recommended to follow the layout guidelines provided in the datasheet to ensure proper performance and minimize noise interference.

Please note that these answers are general and may vary depending on the specific requirements and application of the MAX708TCPA+. It is always advisable to refer to the datasheet and consult with the manufacturer for detailed information.