画像はイメージの場合もございます。
商品詳細は仕様をご覧ください。
FRN-R-1-8/10

FRN-R-1-8/10 Product Overview

Introduction

FRN-R-1-8/10 is a specialized component used in electrical systems for a variety of applications. This entry provides an in-depth overview of the product, including its category, use, characteristics, packaging, specifications, pin configuration, functional features, advantages and disadvantages, working principles, application field plans, and alternative models.

Basic Information Overview

  • Category: Electrical Component
  • Use: Used in electrical systems for protection and control
  • Characteristics: High thermal stability, reliable performance, compact design
  • Package: Typically sold in sealed packaging to prevent damage during transportation and storage
  • Essence: Provides overcurrent protection in electrical circuits
  • Packaging/Quantity: Available in packs of 10 units

Specifications

  • Model: FRN-R-1-8/10
  • Rated Current: 8A
  • Voltage Rating: 250V
  • Breaking Capacity: 10kA
  • Operating Temperature: -40°C to 85°C
  • Dimensions: 10mm x 38mm

Detailed Pin Configuration

The FRN-R-1-8/10 features a standard blade-style terminal for easy installation in compatible electrical systems. The detailed pin configuration includes: - Terminal 1: Input - Terminal 2: Output

Functional Features

  • Overcurrent Protection: Safeguards electrical circuits from excessive current flow
  • Fast Response Time: Quickly interrupts the circuit in case of overcurrent conditions
  • Compact Design: Space-efficient component suitable for various applications

Advantages and Disadvantages

Advantages

  • Reliable Protection: Ensures the safety of electrical systems and connected devices
  • Compact Size: Fits into tight spaces within electrical enclosures
  • Wide Operating Temperature Range: Suitable for diverse environmental conditions

Disadvantages

  • Limited Current Rating: Not suitable for high-current applications exceeding 8A
  • Single-Pole Configuration: May require additional components for multi-pole protection

Working Principles

The FRN-R-1-8/10 operates based on the principle of thermal-magnetic protection. It utilizes a bimetallic strip to sense overcurrent conditions and trigger the interruption of the circuit. The magnetic element provides additional protection by responding to short-circuit events.

Detailed Application Field Plans

The FRN-R-1-8/10 is commonly used in various electrical applications, including: - Control Panels - Motor Control Centers - Industrial Machinery - HVAC Systems - Power Distribution Units

Detailed and Complete Alternative Models

For applications requiring different current ratings or voltage specifications, alternative models to consider include: - FRN-R-2-15/10: 15A rated current, 250V voltage rating - FRN-R-3-20/10: 20A rated current, 250V voltage rating - FRN-R-4-30/10: 30A rated current, 250V voltage rating

In conclusion, the FRN-R-1-8/10 plays a crucial role in providing overcurrent protection in electrical systems, offering reliable performance and compact design. Its application spans across various industries, and alternative models are available to cater to specific requirements.

Word Count: 443

技術ソリューションにおける FRN-R-1-8/10 の適用に関連する 10 件の一般的な質問と回答をリストします。

  1. What is FRN-R-1-8/10?

    • FRN-R-1-8/10 is a type of fuse designed for use in electrical circuits to protect against overcurrent and short circuits.
  2. What are the typical applications of FRN-R-1-8/10 fuses?

    • FRN-R-1-8/10 fuses are commonly used in industrial machinery, control panels, and power distribution systems to provide overcurrent protection.
  3. What is the voltage rating of FRN-R-1-8/10 fuses?

    • The voltage rating of FRN-R-1-8/10 fuses is typically 250V or 600V, depending on the specific model.
  4. What is the current rating of FRN-R-1-8/10 fuses?

    • The current rating of FRN-R-1-8/10 fuses is 1-8/10 amps, which means they can handle currents within this range before blowing.
  5. How do I select the right FRN-R-1-8/10 fuse for my application?

    • To select the right FRN-R-1-8/10 fuse, you need to consider the operating voltage, maximum current, and the type of circuit it will be used in.
  6. Can FRN-R-1-8/10 fuses be used in both AC and DC circuits?

    • Yes, FRN-R-1-8/10 fuses are suitable for use in both AC and DC circuits, but it's important to ensure that the voltage and current ratings match the application.
  7. Are FRN-R-1-8/10 fuses interchangeable with other fuse types?

    • FRN-R-1-8/10 fuses are not generally interchangeable with other fuse types, so it's important to use the specific fuse recommended for your equipment.
  8. What are the temperature and environmental considerations for FRN-R-1-8/10 fuses?

    • FRN-R-1-8/10 fuses have specific temperature and environmental ratings, so it's important to ensure they are used within their specified operating conditions.
  9. How do I replace a blown FRN-R-1-8/10 fuse?

    • To replace a blown FRN-R-1-8/10 fuse, first, disconnect the power supply, then remove the old fuse and insert a new one with the same voltage and current ratings.
  10. Where can I purchase FRN-R-1-8/10 fuses?

    • FRN-R-1-8/10 fuses can be purchased from electrical supply stores, online retailers, and authorized distributors of electrical components.